Agent skill · Code Review & Quality

hydrothermal-synthesis-carbon-dots-180c-dual-0.22um-filtration

A reusable, execution-grade protocol for hydrothermal synthesis of carbon dots (e.g., from citric acid and urea) that enforces a strict 180 °C reaction temperature to prevent PTFE liner deformation and mandates two non-optional 0.22 μm aqueous syringe filtrations — one post-reaction and one post-dialysis — as lab-mandated quality control steps.

ECNU-ICALKgithub.com/ECNU-ICALKGitHub ↗
claude-code
Install
npx skills add ECNU-ICALK/AutoSkill --skill hydrothermal-synthesis-carbon-dots-180c-dual-0-22um-filtration --agent claude-code

Same command for any agent — swap --agent for codex, cursor, copilot.

Facts
Files in the skill folder: 1
SKILL.md size: 4 KB
Bundled scripts: none
Version: 0.1.1
Path: SkillBank/Users/u38/hydrothermal-synthesis-carbon-dots-180c-dual-0-22um-filtration/SKILL.md
Open the folder on GitHub →
Where it comes from
Stars: 539
Language: Python

Weekly change comes from our own snapshots, not the repository page — it measures attention, not adoption.

From the SKILL.md

# hydrothermal-synthesis-carbon-dots-180c-dual-0.22um-filtration A reusable, execution-grade protocol for hydrothermal synthesis of carbon dots (e.g., from citric acid and urea) that enforces a strict 180 °C reaction temperature to prevent PTFE liner deformation and mandates two non-optional 0.22 μm aqueous syringe filtrations — one post-reaction and one post-dialysis — as lab-mandated quality control steps. ## Prompt # Goal Generate a fully executable, step-by-step laboratory procedure for hydrothermal synthesis of carbon dots using user-specified precursors (e.g., citric acid + urea), strictly adhering to thermal hardware limits and dual-filtration quality gates. # Constraints & Style - Reaction temperature MUST be exactly 180 °C — no higher, no rounding, no approximation; state "180 °C" unambiguously in all references. - Hold time at 180 °C MUST default to 4 h unless explicitly overridden by user; do not suggest >4 h without confirmation. - Two mandatory 0.22 μm aqueous-phase syringe filtrations are required: first immediately after cooling and opening the reactor (to remove particulates and PTFE debris), second after dialysis and before final storage (as final sterility/purity

What's inside
Steps it walks through
  1. Prompt
  2. Triggers
More from AutoSkill
All skills →
About this skill
What does the hydrothermal-synthesis-carbon-dots-180c-dual-0.22um-filtration skill do?

A reusable, execution-grade protocol for hydrothermal synthesis of carbon dots (e.g., from citric acid and urea) that enforces a strict 180 °C reaction temperature to prevent PTFE liner deformation and mandates two non-optional 0.22 μm aqueous syringe filtrations — one post-reaction and one post-dialysis — as lab-mandated quality control steps.

How do I install it?

Run `npx skills add ECNU-ICALK/AutoSkill --skill hydrothermal-synthesis-carbon-dots-180c-dual-0-22um-filtration --agent claude-code` — it drops the skill into your project so the agent can pick it up. Swap the --agent value for codex, cursor or copilot if you use one of those.

Where does this skill come from?

From ECNU-ICALK/AutoSkill, a repository with 539 stars. We read it straight from the repository tree rather than a submitted listing, so what you see here is what is actually published.

Is a popular skill a good skill?

Not necessarily. Stars measure attention, not adoption — a repository can trend for a week and be abandoned. That is why we show the weekly change from our own snapshots next to the total, instead of a single flattering number.

Keep going